热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

SJ 20725-1998 MF18型低温温度补偿热敏电阻组件详细规范

作者:标准资料网 时间:2024-05-19 10:37:11  浏览:9493   来源:标准资料网
下载地址: 点击此处下载
基本信息
标准名称:MF18型低温温度补偿热敏电阻组件详细规范
英文名称:Detail specification for module at low temperature for temperature compensation thermistors for Type MF18
中标分类:
发布部门:中华人民共和国信息产业部
发布日期:1998-03-18
实施日期:1998-05-01
首发日期:1900-01-01
作废日期:1900-01-01
归口单位:中国电子技术标准化研究所
起草单位:中国科学院新疆物理所
起草人:妥万禄、沈波
出版社:电子工业出版社
出版日期:1998-04-01
页数:13页
适用范围

本规范规定了MF 18型低温温度补偿热敏电阻组件(以下简称组件)的技术要求,质量保证,检验方法和交货准备等。本规范适用于MF 18型低温温度补偿热敏电阻组件。

前言

没有内容

目录

没有内容

引用标准

GB 191-1990 包装储运图示标志
GJB 360A-1996 电子及电气元件试验方法

所属分类:
下载地址: 点击此处下载
Product Code:SAE J2517
Title:Hybrid III Family Chest Potentiometer Calibration Procedure
Issuing Committee:Dummy Testing And Equipment Committee
Scope:This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent non-linearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is non-linear. Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/(volt/volt) or mm/(mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the non-linearity and others did not. Of those that did correct for the non-linearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Subcommittee (DTES), and led to overall variability in chest compression measurements between laboratories. The intent of this SAE Recommended Practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin to test this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The calibration procedure recommended here uses a two-point calibration and is not intended to correct for the non-linearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also does not require the measurement of a starting position of the potentiometer before each crash test, thus it does not correct for the difference in starting chest geometry between a subject dummy and its design intent. It is intended to be a simple and reproducible calibration procedure which crash test facilities can easily adopt with little or no modifications to their facilities. More complex procedures could in fact address the non-linearity, but at the likely cost of non-adoption by some facilities.【英文标准名称】:Electricalapparatusforpotentiallyexplosiveatmospheres;generalrequirements
【原文标准名称】:爆炸危险区域用电气器材.一般规程.修订3
【标准号】:DINVDE0170/0171-1/A3-1984
【标准状态】:作废
【国别】:德国
【发布日期】:1984-05
【实施或试行日期】:
【发布单位】:德国标准化学会(DIN)
【起草单位】:
【标准类型】:()
【标准水平】:()
【中文主题词】:安全工程;电气安全;爆炸性环境;防爆;规范(审批);电驱动装置;电气外壳;防火外壳;电气工程;材料;试验;外壳;作标记;可燃性环境
【英文主题词】:
【摘要】:
【中国标准分类号】:K35
【国际标准分类号】:1180
【页数】:13P;A4
【正文语种】:德语



版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1